EATON UPS 5PX 3000i RT3U G2, Line-interactive, Rack 3U/Tower, 3000VA/3000W, výstup 8/2x IEC C13/C19, USB

 
 
 
 
 
 
 
  • EATON UPS 5PX 3000i RT3U G2, Line-interactive, Rack 3U/Tower, 3000VA/3000W, výstup 8/2x IEC C13/C19, USB
  • EATON UPS 5PX 3000i RT3U G2, Line-interactive, Rack 3U/Tower, 3000VA/3000W, výstup 8/2x IEC C13/C19, USB
  • EATON UPS 5PX 3000i RT3U G2, Line-interactive, Rack 3U/Tower, 3000VA/3000W, výstup 8/2x IEC C13/C19, USB
 
 
 
 
 
 
 
 
 
 
Kód:
5PX3000IRT3UG2
P/N:
5PX3000IRT3UG2
Výrobce:

Eaton záložní zdroje 

Záruka:
36 Měsíců
 
 

ks.

 
PRA - Sklad Praha,
BRA - Sklad HL Bratislava,
EXT - Externí sklad: Pro termín dodání kontaktujte svého obchodníka
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  •  
 

Související produkty

 
 
 
 

Související produkty  (12)

 
 
 

ks.

 
 
 

Výrobce:  Eaton příslušenství 

P/N: EBP-1613I

ks.

 
 
 
 
 
 
 
 
 
  •  
 

Podrobnosti o produktu

 
 
 

Popis produktu:

Exceptional efficiency, manageability and energy metering capabilities for IT managers

Performance and efficiency
• Eaton 5PX Gen 2 provides Unity power factor (W=VA) capability. With 11% more power than other UPS it can protect more servers.
• Energy Star 2.0 certified, 5PX Gen2 offers best-in-class efficiency performance to reduce energy consumption and cooling costs.
• When operating in battery mode the 5PX provides a high-quality output signal for any sensitive equipment connected, such as active PFC (power factor corrected) servers.
• Each 5PX Gen2 battery configuration provides the best size/ runtime ratio.

Management and Cybersecurity
• Innovative graphical LCD display brings all operating information at first sight. It also enhances commissioning and configuration capabilities.
• 5PX Gen2 Netpack models are delivered with Eaton Gigabit network management card, which provides Dual cybersecurity certifications (UL 2900-1 & IEC 62443-4-2) and enables connection to Eaton Cyber Secured Monitoring solutions.
• Together with 5PX Gen2, Eaton Gigabit network management card allows both remote UPS settings and remote firmware upgrade to ensure easy deployment (fleet management) and reduced maintenance cost.
• 5PX Gen2 meters energy consumption right down to the managed outlet groups. kWh values can be monitored using the LCD or Eaton’s Intelligent Power Software.
• Eaton’s Intelligent Power Software seamlessly integrates with leading virtualization environments and cloud orchestration tools.

Availability and flexibility
• 5PX Gen2 2200VA & 3000VA are available in RT2U format (optimized for rack mounting) or RT3U (for tower installation or short-depth racks). Pedestals and rail kits are included with all models.
• 5PX Gen2 load segment control enables prioritized shutdowns of non-essential equipment to maximize battery runtime for critical devices (2 groups).
• Eaton ABM® battery management technology uses a threestage charging technique that optimizes battery health and extends lifetime by up to 50%.
• Up to 4 external hot-swappable battery modules can be added for longer power availability.


Stránky o produktu:

https://www.eaton.com/cz/cs-cz/skuPage.5PX3000IRTNG2.specifications.html


 
 
 
 
 
 
 
 

Parametry

 
 
 

Základní parametry
Účel použití:  Pro servery
Provedení:  Rack/Tower
Technologie:  Line interactive
Možnost externí baterie:  ANO

Vstupy a výstupy
Vstupy:  IEC C20 (16A)
Výstupy:  IEC C13 (10A) + IEC C19 (16A)
Počet výstupů:  8+2
Fáze (Vstup/Výstup):  1:1

Výkon
Výkon (VA):  1601-3000 VA
Výkon (W):  1351-3000 W

Vlastnosti
Komunikační rozhraní:  USB/RS-232/slot pro LAN
Ventilátor:  ANO
Management karta:  Volitelné
Čistá sinusoida:  ANO
 
 
 
 
 
 
 

Zařazení produktu

 
 
 
 
 
 
 
 

Související dokumenty

 
 
 
 
 
 
 
 
 
 

Poslat info

 
 
 
 

Nalezli jste jinde na internetu nižší cenu?

 
 
 
 
Váš e-mail:
Cena bez DPH:
Cena s DPH:
WWW:
Komentář:
Mám o tento produkt zájem: 
Opište kód z obrázku:  Jiný obrázek...
 
 
 
 
 
 
 
 

Zaslat informaci o produktu známému

 
 
 
Váš e-mail:
Zaslat na e-mail:
Komentář:
Opište kód z obrázku:  Jiný obrázek...
 
 
 
 
 
 
 
 

Nalezli jste chybu?

 
 
 
Popis závady
Váš e-mail
Opište kód z obrázku:  Jiný obrázek...